SADDLE METHOD




Foilboard Saddles make underfloor insulation installation straightforward and effective. Designed for timber and steel frames in new builds, they hold insulation panels securely between joists, ensuring proper positioning and stability. By maintaining a reflective air gap, Saddles optimize thermal performance, enhancing energy efficiency and indoor comfort. This simple accessory ensures a durable and precise underfloor insulation solution.
INSTALLATION ACCESSORIES
**Foilboard Insulation Panel Dimension: 240mm x 1200mm (2.88m2)**
Total System R Values Saddle / Timber Joist
FOILBOARD PANEL | REFLECTIVE AIRSPACE ABOVE FOILBOARD | HEAT FLOW DOWN | HEAT FLOW UP |
---|---|---|---|
GREEN 20 | 20MM | Rt2.8 | Rt2.0 |
GREEN 15 | 25MM | Rt2.7 | Rt1.9 |
GREEN 10 | 30MM | Rt2.7 | Rt1.8 |
System Description: Suspended Timber Floor, Sealed Airspace above Foilboard, Enclosed subfloor, 19mm Tongue and Groove Flooring. 140x45mmx1.9mm timber joist at 450mm c/c. 300x50mm Pine Bearer at 3600mm c/c. Ground Thermal Resistance based on subfloor ventilation area per perimeter length 6000mm2/m = R0.58 heat flow out and R0.56 Heat Flow In. Foilboard Installed antiglare up. Fully Sealed air space assumes no dust cover on upward facing surfaces. Enclosed cavity to prevent air ingress.
Calculated per AS/NZS 4859 Part 1 & 2:2018.
If elements of construction vary from that described, this may produce a different thermal resistance result.
Total System R Values Saddle / Steel Joist
FOILBOARD PANEL | REFLECTIVE AIRSPACE ABOVE FOILBOARD | HEAT FLOW DOWN | HEAT FLOW UP |
---|---|---|---|
GREEN 20 | 20MM | Rt2.2 | Rt1.7 |
GREEN 15 | 25MM | Rt2.2 | Rt1.6 |
GREEN 10 | 30MM | Rt2.2 | Rt1.6 |
System Description: Suspended Timber Floor, Sealed Airspace above Foilboard, Enclosed subfloor, 19mm Tongue and Groove Flooring. 150x50mmx1.9mm Steel joist at 450mm c/c. 250x50mm Steel Bearer at 5600mm c/c. Ground Thermal Resistance based on subfloor ventilation area per perimeter length 6000mm2/m = R0.58 heat flow out and R0.56 Heat Flow In. Foilboard Installed antiglare up. Fully Sealed air space assumes no dust cover on upward facing surfaces. Enclosed cavity to prevent air ingress.
Calculated per AS/NZS 4859 Part 1 & 2:2018.
If elements of construction vary from that described, this may produce a different thermal resistance result.
If the R-Value required for your project is not listed in the table above, please complete the Underfloor R-Value Request Form and submit the necessary project details.
DISCLAIMER All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy thereof is not guaranteed. Users assume all risk and liability resulting from the use of the product and must confirm the suitability thereof by their own calculations. Conditions of Sale contain a limited warranty against manufacturing defects. Where applicable, Foilboard GREEN should be installed per the National Construction Code (NCC), state building legislation and/or a performance solution.
Added Insulation R Values Saddle / Timber Joist
FOILBOARD PANEL | REFLECTIVE AIRSPACE ABOVE FOILBOARD | HEAT FLOW DOWN | HEATFLOW UP |
---|---|---|---|
GREEN 20 | 20MM | R1.8 | R1.0 |
GREEN 15 | 25MM | R1.8 | R0.9 |
GREEN 10 | 30MM | R1.7 | R0.8 |
System Description: Suspended Timber Floor, Sealed Airspace above Foilboard, Enclosed subfloor, 19mm Tongue and Groove Flooring. 140x45 timber joist at 450mm c/c. 300x50mm Pine Bearer at 3600mm c/c. Ground Thermal Resistance based on subfloor ventilation area per perimeter length 6000mm2/m = R0.58 heat flow out and R0.56 Heat Flow In. Foilboard Installed antiglare up. Fully Sealed air space assumes no dust cover on upward facing surfaces. Enclosed cavity to prevent air ingress. Calculated per AS/NZS 4859 Part 1 & 2:2018. Added Insulation R Value includes the material insulation R Value and the R Values of the associated reflective airspaces within the insulation system less non-reflective enclosed subfloor air film.
If elements of construction vary from that described, this may produce a different thermal resistance result.
Added Insulation R Values Saddle / Steel Joist
FOILBOARD PANEL | REFLECTIVE AIRSPACE ABOVE FOILBOARD | HEAT FLOW DOWN | HEATFLOW UP |
---|---|---|---|
GREEN 20 | 20MM | R1.8 | R1.1 |
GREEN 15 | 25MM | R1.8 | R0.9 |
GREEN 10 | 30MM | R1.7 | R0.8 |
System Description: Suspended Timber Floor, Sealed Airspace above Foilboard, Enclosed subfloor, 19mm Tongue and Groove Flooring. 150x50mmx1.9mm Steel joist at 450mm c/c. 250x50mm Steel Bearer at 5600mm c/c. Ground Thermal Resistance based on subfloor ventilation area per perimeter length 6000mm2/m = R0.58 heat flow out and R0.56 Heat Flow In. Foilboard Installed antiglare up. Fully Sealed air space assumes no dust cover on upward facing surfaces. Enclosed cavity to prevent air ingress. Calculated per AS/NZS 4859 Part 1 & 2:2018. Added Insulation R Value includes the material insulation R Value and the R Values of the associated reflective airspaces within the insulation system less non-reflective enclosed subfloor air film.
If elements of construction vary from that described, this may produce a different thermal resistance result.
If the R-Value required for your project is not listed in the table above, please complete the Underfloor R-Value Request Form and submit the necessary project details.
DISCLAIMER All statements and technical information contained herein are based on tests we believe to be reliable, but the accuracy thereof is not guaranteed. Users assume all risk and liability resulting from the use of the product and must confirm the suitability thereof by their own calculations. Conditions of Sale contain a limited warranty against manufacturing defects. Where applicable, Foilboard GREEN should be installed per the National Construction Code (NCC), state building legislation and/or a performance solution.